First Mechanical Watch

First Mechanical Watch

An automatic or self-winding watch is a mechanical watch in which the mainspring is wound automatically as a result of natural motion of the wearer's arm, to provide energy to run the watch, making manual winding unnecessary. A mechanical watch which is neither self-winding nor electrically driven is called a manual watch. Most mechanical watches manufactured today are self-winding.

Operation[edit]

A mechanical watch is powered by an internal spiral mainspring which turns the gears that move the hands. The spring loses energy as the watch runs, so in a manual watch movement the spring must be wound periodically by turning a small knob on the case, the crown, to provide energy to run the watch. Otherwise, once the energy in the mainspring runs out, and it stops.

A self-winding watch movement has a mechanism which winds the mainspring. The watch contains an eccentric weight (the rotor), which turns on a pivot. The normal movements of the user's arm cause the rotor to pivot on its staff, which is attached to a ratcheted winding mechanism. The motion of the wearer's arm is thereby translated into circular motion of the rotor which, through a series of reverser and reducing gears, eventually winds the mainspring. There are many different designs for modern self-winding mechanisms. Some designs allow winding of the watch to take place while the rotor swings in only one direction while other, more advanced, mechanisms have two ratchets and wind the mainspring during both clockwise and counterclockwise rotor motions.

The fully wound mainspring in a typical watch can store enough energy reserve for roughly two days, allowing the watch to keep running through the night while stationary. In many cases automatic watches can also be wound manually by turning the crown, so the watch can be kept running when not worn, and in case the wearer's wrist motions are not sufficient to keep it wound automatically.

[edit]

Self-winding mechanisms continue working even after the mainspring is fully wound up. If a simple mainspring was used, this would put excessive tension on the mainspring. This could break the mainspring, and even if it did not, it can cause a problem called "knocking" or "banking". The excessive drive force applied to the watch movement gear train can make the balance wheel rotate with excessive amplitude, causing the impulse pin to hit the back of the pallet fork horns. This will make the watch run fast, and could break the impulse pin. To prevent this, a slipping clutch device is used on the mainspring so it cannot be overwound.

The slipping spring or "bridle"[edit]

The "slipping mainspring" device was patented by Adrien Philippe, one of the founders of Patek Philippe, on 16 June 1863, long before self-winding watches. It was invented to allow simultaneous winding of two mainspring barrels. In an ordinary watch mainspring barrel, the outer end of the spiral mainspring is attached to the inside of the barrel. In the slipping barrel, the mainspring is attached to a circular steel expansion spring, often called the 'bridle', which presses against the inside wall of the barrel, which has serrations or notches to hold it.

As long as the mainspring is less than fully wound, the bridle holds the mainspring by friction to the barrel wall, allowing the mainspring to be wound. When the mainspring reaches full wind, its force is stronger than the bridle spring, and further winding pulls the bridle loose from the notches and it simply slides along the wall, preventing the mainspring from being wound further. The bridle must grip the barrel wall with just the right force to allow the mainspring to wind fully but not overwind. If it grips too loosely, the bridle will begin to slip before the mainspring is fully wound, a defect known as 'mainspring creep' which results in a shortened reserve power time.

A further advantage of this device is that the mainspring cannot be broken by excessive manual winding. This feature is often described in watch company advertising as an "unbreakable mainspring".

Automatic quartz or kinetic movement[edit]

After the introduction of quartz watches, electronic automatic quartz watches powered by arm movement were developed by Seiko. Typically a weighted rotor turns a tiny electrical generator, charging a rechargeable battery or low-leakage capacitor, which powers the quartz movement. This automatic quartz arrangement provides the accuracy of a quartz movement without the need for routine battery replacement. An alternative power source with functionally similar results is a photoelectric cell ("solar watch").

Source: en.wikipedia.org
RELATED VIDEO
Breva Genie01 - the world first mechanical watch with
Breva Genie01 - the world first mechanical watch with ...
The First Hybrid Mechanical Smartwatch | KAIROS Baselworld
The First Hybrid Mechanical Smartwatch | KAIROS Baselworld ...
@LAMONTREMOBILE (WATCHe) : First mechanical watch on Apple
@LAMONTREMOBILE (WATCHe) : First mechanical watch on Apple ...
RELATED FACTS
Share this Post

Related posts

How mechanical Watches work

How mechanical Watches work

SEPTEMBER 20, 2017

Left unchecked, this mainspring would quickly unwind and give up its energy in an instant. Therefore, the barrel that houses…

Read More
Who invented the first mechanical clock?

Who invented the first mechanical clock?

SEPTEMBER 20, 2017

A turret clock or a public clock is a clock that is larger than a domestic clock and has a mechanism designed to drive a…

Read More